# Prepare RFID reader for Smart Fitting Room

> Configure a supported RFID reader so it can detect garments inside the fitting room.

## How to configure Zebra FX9600 RFID reader

  1. [Update the Zebra FX9600 device](https://support.zebra.com/article/Update-FX-Series-Fixed-RFID-Reader-Software-Version) to software version **3.26.90**
  2. [Perform a factory reset of the RFID reader](https://support.zebra.com/article/Factory-Reset-FX-Series-Fixed-RFID-Reader) by holding down the reset button for 8 seconds or by selecting the Enterprise Reset option in the web interface's Shutdown section
  3. Enter the Zebra web interface by opening `https://fx9600******/` or `http://<reader-ip>/` in your web browser - the asterisks are the last six digits of the reader's MAC address, usually found on the side of the reader itself
     - Ignore any security warning and proceed to the login page
     - Use the default username `admin` and password `change` if you are logging in for the first time
     - You will be asked to set a new password
  4. Set the region-related RFID settings
  5. Under **Zebra IoT Connector** → **Configuration**, click **Add Endpoint**
  6. Select **HTTP Post** as endpoint type
  7. Enter the **Endpoint Name**
  8. Enter `http://<phyos-device-ip-address>:3001/zebra` as the URL
     - You can get your PhyOS device IP on the device settings page
  9. Set **Authentication Type** to **None**
  10. Click **Add**
  11. Select this endpoint in **Tag Data Interface** and **Management Events Interface**, and activate **Local Rest Management** and **Local Rest Control** if those options are available
  12. Click Update
  13. Open **Zebra IoT Connector** → **Connection** and click **Connect**
  14. All four statuses should show **Connected**